Safeguard your mission-critical infrastructure with our industry-leading 10kVA uninterruptible power supplies. Engineered for demanding environments, our UPS systems deliver unmatched reliability, scalability, and performance. Protect data centers, telecommunications networks, industrial facilities, and enterprise operations from power disruptions—ensuring 99.99% uptime and zero business interruption.
The RM11-H Series is a newly developed, next-generation general-purpose UPS designed to provide reliable power protection. Featuring a flexible tower and rack-mount compatible design and an online double-conversion topology, it effectively protects equipment from power outages, over-voltage and under-voltage conditions, voltage sags and surges, fluctuations, harmonic distortion, electrical noise, and frequency variations, ensuring a clean and stable power supply.
IT loads for government, finance, education, and small/medium enterprises and institutions.
| Model | 01L-H | 01-H | 02L-H | 02H | 03L-H | 03-H | 06L-H | 06-H | 10L-H | 10-H | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 01L-UNR | 01-UNR | 02L-UNR | 02-UNR | 03L-UNR | 03-UNR | 06L-UNR | 10L-UNR | ||||
| Capacity | 1KVA | 2KVA | 3KVA | 6KVA | 10KVA | ||||||
| Input | Input wiring | L + N + PE | |||||||||
| Rated voltage | 208 / 220 / 230 / 240VAC | ||||||||||
| Voltage range | 0 ~ 300VAC | ||||||||||
| Frequency range | 44 ~ 56Hz @ 50Hz / 54Hz ~ 66Hz @ 60Hz | ||||||||||
| Power factor | ≥ 0.99 | ||||||||||
| Output | Output wiring | L + N + PE | |||||||||
| Output voltage | 208 / 220 / 230 / 240VAC | ||||||||||
| Output accuracy | ±1% | ||||||||||
| Output frequency | Online mode: follows utility frequency; Battery mode: 50/60 Hz ± 0.05 | ||||||||||
| THDv | ≤ 2% (linear load); ≤ 5% (non-linear load) | ||||||||||
| Power factor | 0.8 | ||||||||||
| Transfer time | Utility → Battery: 0 ms; Inverter → Bypass: 4 ms | ||||||||||
| Overload capability |
Utility mode: 30 min @ 102%-0% load; 10 min @ 0%-130% load; 30 s @ 130%-150% load; 200 ms @ >150% load Battery mode: 30 min @ 102%-0% load; 10 min @ 0%-130% load; 30 s @ 130%-150% load; 200 ms @ >150% load | ||||||||||
| Efficiency (utility mode) | > 94.5% | > 95.5% | > 95.5% | > 95% | > 95% | ||||||
| Battery | Battery voltage | 36Vdc | Built-in 3x12V 7AH | 72Vdc | Built-in 6x12V 7AH | 96Vdc | Built-in 8x12V 7AH | 192Vdc | Built-in 16x12V 7AH | 192Vdc | Built-in 16x12V 7AH |
| Charging current | 1-12A(max) | 1A | 1-12A(max) | 1A | 1-12A(max) | 1A | 1-12A(max) | 1A | 1-12A(max) | 1A | |
| Display | LCD display shows mode/load/battery/input/output, etc. | ||||||||||
| Communication | Standard RS232; optional SNMP card and USB | ||||||||||
| Environment | Operating temperature | 0 ~ 40°C | |||||||||
| Relative humidity | 20% ~ 95%RH (non-condensing) | ||||||||||
| Altitude | ≤ 1000 m; above 1000 m, derate 1% per 100 m; max. 4000 m (ref. IEC 62040) | ||||||||||
| Dimensions | Tower: L x W x H (mm) | 145x315x319 | 145x400x319 | 145x400x319 | 190x454x322 | 190x454x700 | 190x454x322 | 190x454x700 | |||
| Weight (kg) | 4.1 | 8.3 | 5.7 | 14.1 | 6.4 | 21 | 9.8 | 43.2 | 11.2 | 54.6 | |
| Dimensions | Rack: L x W x H (mm) | 438x315x86.8 | 438x400x86.8 | 438x400x86.8 | 438x500x86.8 | / | 438x500x86.8 | / | |||
| Weight (kg) | 4.8 | 9.8 | 22.6 | 8 | 8.2 | 21 | 8.8 | / | 11 | / | |
A 10kVA UPS (Uninterruptible Power Supply) is the gold standard for protecting large-scale IT infrastructure, data center clusters, server farms, and industrial equipment from power outages, surges, voltage fluctuations, and harmonic distortion. Our 10kVA UPS systems deliver enterprise-class performance, redundancy, and reliability—essential for mission-critical environments where downtime translates directly to business loss. Whether you operate a financial services facility, healthcare provider, telecommunications hub, or manufacturing plant, our 10kVA solutions ensure continuous operations and data integrity.
Every organization has unique power protection requirements. Our power protection experts are standing by to design a tailored 10kVA UPS solution that fits your infrastructure, budget, and operational goals. Benefit from:
Achieve 99.99% system availability with zero-transfer switching and redundant architectures. Prevent costly downtime that impacts operations, revenue, and customer confidence.
Safeguard databases, applications, and intellectual property from corruption due to unexpected power loss. Ensure data integrity and regulatory compliance across your infrastructure.
Modern energy-efficient 10kVA UPS systems cut electricity consumption by 15-25%. Modular designs reduce maintenance expenses and extend equipment lifespan by 30-50%.
Automated monitoring and cloud-based management reduce manual oversight. Real-time alerts enable proactive maintenance, minimizing unexpected issues and emergency support calls.
Meet industry standards (HIPAA, PCI-DSS, SOX, etc.) that mandate backup power for critical systems. Maintain audit trails and compliance documentation automatically.
Scalable, modular architecture grows with your business. Support t-UNRee-phase power, parallel redundancy, and advanced integrations without complete replacement.
A 10kVA UPS is an enterprise-class uninterruptible power supply with a capacity of 10,000 volt-amperes (approximately 8-9 kW at 0.8-0.9 power factor), engineered to deliver robust backup power and protect mission-critical equipment from power disturbances. In today's digital economy, even brief power interruptions can cost enterprises $5,600-$12,000 per minute in lost productivity, data corruption, and operational disruption. A 10kVA UPS protects against downtime, preserves data integrity, and ensures business continuity.
A 10kVA UPS typically supports 15-25+ physical servers, 50-100+ end-user workstations, or equivalent mixed IT infrastructure. Common deployments include: enterprise server racks, data center clusters, telecommunications switching centers, medical imaging facilities, manufacturing control systems, and financial trading floors. Always verify your equipment's total wattage and power factor to ensure compatibility. Our engineers can perform a free power audit to determine optimal sizing.
Premium 10kVA UPS systems include: online double-conversion architecture (zero-transfer-time switching), modular battery design, hot-swappable components, advanced monitoring dashboards, SNMP/web interfaces, cloud integration, predictive analytics, cybersecurity hardening, and optional t-UNRee-phase support. These features ensure maximum uptime, reduced operational costs, and proactive management of your power infrastructure.
Runtime depends on total load and battery configuration. At 50% load (5kVA), most 10kVA systems provide 15-30 minutes of backup. At 25% load (2.5kVA), runtime extends to 45-90+ minutes. Modular battery packs can extend runtime to several hours. Most organizations use UPS systems to bridge power gaps and gracefully shut down systems, rather than sustain operations indefinitely. We recommend battery runtime planning during the initial assessment.
Absolutely. Modern 10kVA UPS systems support comprehensive remote management via web interfaces, mobile apps, SNMP protocols, and cloud platforms. You'll receive real-time alerts for power events, battery status, temperature anomalies, and predictive maintenance needs. This allows IT teams to proactively address issues and ensure uninterrupted operations 24/7/365.
Yes. Many premium 10kVA UPS models support parallel configurations (typically up to 4 units) for N+1 redundancy, where one unit can fail without loss of power protection. This architecture is critical for data centers and critical infrastructure facilities requiring fault tolerance and 99.99%+ uptime SLAs. Our engineers can design a redundant system that meets your availability requirements.
Single-phase UPS systems (120/240V) are ideal for smaller deployments and distributed locations. T-UNRee-phase systems (208V, 380V, 400V, 480V) are designed for data centers and large industrial facilities with t-UNRee-phase power distribution. T-UNRee-phase systems offer better power factor, higher efficiency, and support larger loads. We offer both options—let us know your facility's power distribution architecture.
The ROI is substantial. Consider: average downtime cost = $5,600-$12,000/minute; a 15-minute outage = $84,000-$180,000 in losses. A single prevented outage justifies a 10kVA UPS investment. Additionally, energy-efficient modern UPS systems reduce operational costs by 15-25% compared to older models. Most enterprises see full ROI within 2-3 years. We provide detailed business case analysis during the consultation phase.